Loading...

Altronix ACM8CB Eight PTC Output Access Power Controller

Altronix   |   SKU: ACM8CB   |   Model: ACM8CB

Product Highlights

Altronix ACM8CB Eight PTC Output Access Power Controller
Qty:
$74.65
Add to Quote

Usually ships within 1-2 Weeks + Shipping Method

  • Free Lifetime Support
  • Free Warranty & Repair Service
  • Call for Bulk Pricing
Express Checkout:

The ACM8CB converts one (1) 12 to 24 volt AC or DC input into eight (8) independently controlled PTC protected outputs. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The ACM8CB will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually select-able for any or all of the eight (8) outputs.

Input

  • 12 to 24 volt AC or DC operation (setting not required), (0.6 amp @ 12volt, 0.3 amp @ 24 volt current consumption with all relays energized)
  • Power supply input options:
    • One (1) common power input (board and lock power)
    • Two (2) isolated power inputs (one (1) for board power and one (1) for lock/accessory power)
  • Eight (8) Access Control System trigger inputs:
    • Four (8) normally open (NO) inputs
    • Four (8) open collector sink inputs
    • Any combination of the two

Output

  • Four (8) independently controlled outputs:
    • Four (8) Fail-Safe and/or Fail-Secure power outputs
    • Four (8) dry form "C" 5 amp rated relay outputs
  • Output ratings:
    • PTCs are rated 2.5 amp each
    • Main fuse is rated at 10 amp

Features

  • Fire Alarm disconnect (latching or non-latching) is individually select-able for any or all of the four (8) outputs
  • Fire Alarm disconnect input options:
    • Normally open (NO) or normally closed (NC) dry contact input
    • Polarity reversal input from FACP signaling circuit
  • FACP output relay (form "C" contact rated @ 1 amp 28VDC not evaluated by UL)
  • Removable terminal blocks facilitate ease of installation

Visual Indicators

  • Red LEDs indicate outputs are triggered (relays energized)
  • Green LED indicates FACP disconnect is triggered

Electrical

  • Operating temperature: 0 degree C to 49 degree C ambient
  • BTU/Hr:
    • 12VDC or 12VAC: 3.68 BTU/Hr
    • 24VDC or 24VAC: 3.68 BTU/Hr

Downloads

pdf
(Size: 143.5 KB)
Condition New
Brand Altronix
No of Outputs 8
Output Protection Fuse
Fire Alarm Interface Yes
Trigger Controlled Outputs Yes
Enclosure No
  • (1) Power Controller
  • (1) Manual
  • Lifetime Warranty/li>

The ACM8CB converts one (1) 12 to 24 volt AC or DC input into eight (8) independently controlled PTC protected outputs. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The ACM8CB will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually select-able for any or all of the eight (8) outputs.

Input

  • 12 to 24 volt AC or DC operation (setting not required), (0.6 amp @ 12volt, 0.3 amp @ 24 volt current consumption with all relays energized)
  • Power supply input options:
    • One (1) common power input (board and lock power)
    • Two (2) isolated power inputs (one (1) for board power and one (1) for lock/accessory power)
  • Eight (8) Access Control System trigger inputs:
    • Four (8) normally open (NO) inputs
    • Four (8) open collector sink inputs
    • Any combination of the two

Output

  • Four (8) independently controlled outputs:
    • Four (8) Fail-Safe and/or Fail-Secure power outputs
    • Four (8) dry form "C" 5 amp rated relay outputs
  • Output ratings:
    • PTCs are rated 2.5 amp each
    • Main fuse is rated at 10 amp

Features

  • Fire Alarm disconnect (latching or non-latching) is individually select-able for any or all of the four (8) outputs
  • Fire Alarm disconnect input options:
    • Normally open (NO) or normally closed (NC) dry contact input
    • Polarity reversal input from FACP signaling circuit
  • FACP output relay (form "C" contact rated @ 1 amp 28VDC not evaluated by UL)
  • Removable terminal blocks facilitate ease of installation

Visual Indicators

  • Red LEDs indicate outputs are triggered (relays energized)
  • Green LED indicates FACP disconnect is triggered

Electrical

  • Operating temperature: 0 degree C to 49 degree C ambient
  • BTU/Hr:
    • 12VDC or 12VAC: 3.68 BTU/Hr
    • 24VDC or 24VAC: 3.68 BTU/Hr

Downloads

pdf
(Size: 143.5 KB)
Condition New
Brand Altronix
No of Outputs 8
Output Protection Fuse
Fire Alarm Interface Yes
Trigger Controlled Outputs Yes
Enclosure No
  • (1) Power Controller
  • (1) Manual
  • Lifetime Warranty/li>

Customers also viewed

Check items to add to the cart or select all