AL1012ULACM

Altronix AL1012ULACM 8 Fused Output PSU/Access Power Controller 12VDC

$ 217.1100
Power Supply/Charger with Access power controller - 8 fused non-power limited outputs provide 12VDC @ 10 amp, outputs are individually selectable for Fail-Safe or Fail-Secure operation or as dry form "C" contacts, fire alarm disconnect is selectable by output, AC & battery monitoring, encl. 15.5"H x 12"W x 4.5"D, 115VAC input, UL Listed (UL294), cUL Listed.

SKU: AL1012ULACM

Model: AL1012ULACM

Condition: New

Availability: Usually ships within 5-7 days

$217.11
Add Items to Cart
Contact us

Model AL1012ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC non power limited fuse protected Fail-Safe and/or Fail-Secure outputs with a total of 10 amp continuous supply current. The fire alarm disconnect feature enables emergency egress in the event the fire alarm system is activated. It is individually selectable for any or all of the eight (8) outputs. Model AL1012ULACMCB is a PTC protected version of this unit.

Input:

  • Input 115VAC 60Hz rated @ 2.6 amp.
  • Power supply input options:
    • a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).
    • b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10 amp total).
  • Eight (8) Access Control System trigger inputs.
    • a) Eight (8) normally open (NO) inputs.
    • b) Eight (8) open collector inputs.
    • c) Any combination of the above.

Output:

  • 12VDC @ 10 amp supply current.
  • Eight (8) independently controlled outputs.
  • Eight (8) Fail-Safe and/or Fail-Secure power outputs.
  • Eight (8) auxiliary power outputs (unswitched)
  • Fuses are rated @ 3.5 amp.
  • Filtered and electronically regulated outputs (built-in power supply).

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
  • Fire Alarm disconnect input options:
    • a) Normally open (NO) or normally closed (NC) dry contact input.
    • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC not evaluated by UL).
  • Short circuit and thermal overload protection.
  • Limited Lifetime Warranty
Brand Altronix
Condition New
Power Supply Type Cabinet, Wall Mount
Outputs 8
Surge Protection Fuses
Input Voltage 115 VAC
Output Voltage 12 VDC
Output Current 10.0 Amp
Features UL Listed