Altronix AL642ULADA NAC Power Supply, 4 Class A or 4 Class B Outputs, 24VDC @ 6.5A, 115VAC, Red BC400 Enclosure

Altronix   |   SKU: AL642ULADA   |   Model: AL642ULADA

Product Highlights

Altronix AL642ULADA NAC Power Extenders
Qty:
$413.08
Add to Quote

Usually ships within 1-2 Weeks + Shipping Method

  • Free Lifetime Support
  • Free Warranty & Repair Service
  • Call for Bulk Pricing
Express Checkout:

The AL642ULADA from ALTRONIX is an extremely cost effective 6.5 amp voltage regulated remote NAC Power Extender that may be connected to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and will provide auxiliary power to support system accessories.The AL642ULADA delivers regulated and filtered 24 or 12-volt power up to eight (8) Class B, four (4) Class A or combination of Class B and Class A Notification Appliance Circuits. Additionally, the unit can supply up to 1 amp from continuous AUX output and up to 1 amp from AC disconnected AUX output.The 6.5 amp rated supply current can be divided between the four (4) outputs for powering notification appliances and the AUX outputs. Each output is rated at 2.5 amp max (total not to exceed 6.5 amp), and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. In the AL642ULADA all the outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). An individual output of 4 amp is achieved by paralleling 2 outputs. In non-alarm condition, units provide independent loop supervision for Class A and/or Class B FACP NAC circuits. In the AL642ULADA the event of a loop trouble the FACP will be notified via the steered input (input 1 or input 2). In addition, there are common trouble output terminals (NC, C and NO) which are used to indicate general loop/system trouble. A common trouble input is provided for optional NC (normally closed) devices to report trouble to the FACP. Two (2) FACP signaling outputs can be connected to power extender inputs. These inputs can then be directed to control supervision and power delivery to any combination of the four (4) outputs. The AL642ULADA also feature “Loop Outputâ trouble memory indication to help identify troublesome sporatic loop problems.

Features

  • Short circuit and thermal overload protection
  • Built-in charger for sealed lead acid or gel type battery backup
  • Zero voltage drop upon transfer to battery backup
  • AC input and DC output LED indicators
  • AC fails supervision
  • Low battery and battery presence supervision

Downloads

Condition New
Brand Altronix
Type Indoor Wallmount
Number of Class A NACs 4
Number of Class B NACs 4
Remote Management No

The AL642ULADA from ALTRONIX is an extremely cost effective 6.5 amp voltage regulated remote NAC Power Extender that may be connected to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and will provide auxiliary power to support system accessories.The AL642ULADA delivers regulated and filtered 24 or 12-volt power up to eight (8) Class B, four (4) Class A or combination of Class B and Class A Notification Appliance Circuits. Additionally, the unit can supply up to 1 amp from continuous AUX output and up to 1 amp from AC disconnected AUX output.The 6.5 amp rated supply current can be divided between the four (4) outputs for powering notification appliances and the AUX outputs. Each output is rated at 2.5 amp max (total not to exceed 6.5 amp), and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. In the AL642ULADA all the outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). An individual output of 4 amp is achieved by paralleling 2 outputs. In non-alarm condition, units provide independent loop supervision for Class A and/or Class B FACP NAC circuits. In the AL642ULADA the event of a loop trouble the FACP will be notified via the steered input (input 1 or input 2). In addition, there are common trouble output terminals (NC, C and NO) which are used to indicate general loop/system trouble. A common trouble input is provided for optional NC (normally closed) devices to report trouble to the FACP. Two (2) FACP signaling outputs can be connected to power extender inputs. These inputs can then be directed to control supervision and power delivery to any combination of the four (4) outputs. The AL642ULADA also feature “Loop Outputâ trouble memory indication to help identify troublesome sporatic loop problems.

Features

  • Short circuit and thermal overload protection
  • Built-in charger for sealed lead acid or gel type battery backup
  • Zero voltage drop upon transfer to battery backup
  • AC input and DC output LED indicators
  • AC fails supervision
  • Low battery and battery presence supervision