Altronix MAXIMAL55F 2 Power Supply/Chargers w/Access Power Controllers
Product Highlights
2 Power Supply/Chargers with Access power controllers - Maximal55F Access Power Controller distributes and switches power to access control systems and accessories. It converts a 120VAC 60Hz input into sixteen (16) independently controlled outputs, each set of 8 outputs is 12VDC @ 9.3 amp fuse protected. These Fail-Safe/Fail-Secure power outputs may be converted to dry form "C" contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices.
- Low battery cutoff
- Over voltage protection (OVP)
- AC & battery monitoring
- Encl. 26"H x 19"W x 6.25"D
- 115VAC input
- Accommodates up to 4 - 12VDC/12AH batteries
- UL Listed (UL294), cUL Listed (ULC-S319-05), CSFM Approved
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
- Fire Alarm disconnect input options:
a) Normally open (NO) or normally closed (NC) dry contact input
b) Polarity reversal input from FACP signaling circuit.
- Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC)
Downloads
Condition | New |
---|---|
Brand | Altronix |
Output Type | DC |
Fire Alarm Interface | Yes |
Certifications | CE, CSFM, cUL, UL |
Power Options | 9.3 amp @ 12VDC plus 9.3 amp @ 12VDC |
Output Protection | Fuse |
Number of Outputs | 16 |
Input Voltage | 120VAC |
Battery Charging | Yes |
2 Power Supply/Chargers with Access power controllers - Maximal55F Access Power Controller distributes and switches power to access control systems and accessories. It converts a 120VAC 60Hz input into sixteen (16) independently controlled outputs, each set of 8 outputs is 12VDC @ 9.3 amp fuse protected. These Fail-Safe/Fail-Secure power outputs may be converted to dry form "C" contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices.
- Low battery cutoff
- Over voltage protection (OVP)
- AC & battery monitoring
- Encl. 26"H x 19"W x 6.25"D
- 115VAC input
- Accommodates up to 4 - 12VDC/12AH batteries
- UL Listed (UL294), cUL Listed (ULC-S319-05), CSFM Approved
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
- Fire Alarm disconnect input options:
a) Normally open (NO) or normally closed (NC) dry contact input
b) Polarity reversal input from FACP signaling circuit.
- Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC)
Downloads
Condition | New |
---|---|
Brand | Altronix |
Output Type | DC |
Fire Alarm Interface | Yes |
Certifications | CE, CSFM, cUL, UL |
Power Options | 9.3 amp @ 12VDC plus 9.3 amp @ 12VDC |
Output Protection | Fuse |
Number of Outputs | 16 |
Input Voltage | 120VAC |
Battery Charging | Yes |