Altronix MAXIMAL7FD Power Supply/Charger with Access Power Controllers
Product Highlights
Power Supply/Charger with Access power controllers - 16 PTC power-limited outputs, 16 outputs are 24VDC @ 9.4 amp, outputs are individually selectable for Fail-Safe or Fail-Secure operation, fire alarm disconnect is selectable by output, Features: Low battery cutoff, Over voltage protection (OVP), AC & battery monitoring, encl. 26"H x 19"W x 6.25"D, 115VAC input, Accommodates up to 4 - 12VDC/12AH batteries, UL Listed (UL294), cUL Listed (ULC-S319-05), CSFM Approved.
Maximal7FD Access Power Controller distributes and switches power to access control systems and accessories. It converts a 120VAC 60Hz input into sixteen (16) independently controlled 24VDC power-limited PTC protected outputs. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. All interconnecting equipment must be UL Listed.
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
- Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit
- Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC)
Downloads
Condition | New |
---|---|
Brand | Altronix |
Output Type | DC |
Fire Alarm Interface | Yes |
Certifications | CE, CSFM, cUL, UL |
Power Options | 9.2 amp @ 24VDC |
Output Protection | PTC |
Number of Outputs | 16 |
Input Voltage | 120VAC |
Battery Charging | Yes |
Power Supply/Charger with Access power controllers - 16 PTC power-limited outputs, 16 outputs are 24VDC @ 9.4 amp, outputs are individually selectable for Fail-Safe or Fail-Secure operation, fire alarm disconnect is selectable by output, Features: Low battery cutoff, Over voltage protection (OVP), AC & battery monitoring, encl. 26"H x 19"W x 6.25"D, 115VAC input, Accommodates up to 4 - 12VDC/12AH batteries, UL Listed (UL294), cUL Listed (ULC-S319-05), CSFM Approved.
Maximal7FD Access Power Controller distributes and switches power to access control systems and accessories. It converts a 120VAC 60Hz input into sixteen (16) independently controlled 24VDC power-limited PTC protected outputs. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. All interconnecting equipment must be UL Listed.
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
- Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit
- Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC)
Downloads
Condition | New |
---|---|
Brand | Altronix |
Output Type | DC |
Fire Alarm Interface | Yes |
Certifications | CE, CSFM, cUL, UL |
Power Options | 9.2 amp @ 24VDC |
Output Protection | PTC |
Number of Outputs | 16 |
Input Voltage | 120VAC |
Battery Charging | Yes |