Loading...

Altronix AL400ULACM Power Supply/Chargers w/Access Power Controllers

Altronix   |   SKU: AL400ULACM   |   Model: AL400ULACM

Product Highlights

Altronix AL400ULACM Power Supply/Chargers w/Access Power Controllers
Qty:
$245.35
Add to Quote

Usually ships within 1-2 Weeks + Shipping Method

  • Free Lifetime Support
  • Free Warranty & Repair Service
  • Call for Bulk Pricing
Express Checkout:

Power Supply/Charger with Access Power Controller - 8 fused Class 2 power limited outputs provide 12VDC @ 4 amp or 24VDC @ 3 amp, outputs are individually selectable for Fail-Safe or Fail-Secure operation or as dry form "C" contacts, fire alarm disconnect is selectable by output, AC & battery monitoring, encl. 15.5"H x 12"W x 4.5"D, 115VAC input, UL Listed (UL294), cUL Listed, CSFM & MEA Approved. AL400ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 4 amp @ 12VDC or 3 amp @ 24VDC continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

  • Input 115VAC 60Hz rated @ 3.5 amp
  • Power supply input options:
  • One (1) common power input for ACM8/ACM8CB and lock power (factory installed)
  • Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10 amp total)
  • Eight (8) Access Control System trigger inputs
  • 12VDC or 24VDC outputs
  • 12VDC @ 4 amp supply current or 24VDC @ 3 amp supply current
  • Class 2 Rated power limited outputs
  • Eight (8) auxiliary power outputs (unswitched)
  • Filtered and electronically regulated outputs (built-in power supply)

Downloads

Condition New
Brand Altronix
Power Supply Type Cabinet, Wall Mount
Output Protection Fuses
Input Voltage 115 VAC
Output Voltage 12 VDC, 24 VDC
Output Current 3.0 Amp, 4.0 Amp
Features Battery Charger, Fire Alarm Disconnect, UL Listed
Output Type DC
Fire Alarm Interface Yes
Certifications CSFM, MEA, UL
Power Options 3 amp @ 24VDC, 4 amp @ 12VDC
Output Protection Fuse
Number of Outputs 8
Input Voltage 115VAC
Version Indoor Wallmount
Battery Charging Yes

Power Supply/Charger with Access Power Controller - 8 fused Class 2 power limited outputs provide 12VDC @ 4 amp or 24VDC @ 3 amp, outputs are individually selectable for Fail-Safe or Fail-Secure operation or as dry form "C" contacts, fire alarm disconnect is selectable by output, AC & battery monitoring, encl. 15.5"H x 12"W x 4.5"D, 115VAC input, UL Listed (UL294), cUL Listed, CSFM & MEA Approved. AL400ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 4 amp @ 12VDC or 3 amp @ 24VDC continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

  • Input 115VAC 60Hz rated @ 3.5 amp
  • Power supply input options:
  • One (1) common power input for ACM8/ACM8CB and lock power (factory installed)
  • Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10 amp total)
  • Eight (8) Access Control System trigger inputs
  • 12VDC or 24VDC outputs
  • 12VDC @ 4 amp supply current or 24VDC @ 3 amp supply current
  • Class 2 Rated power limited outputs
  • Eight (8) auxiliary power outputs (unswitched)
  • Filtered and electronically regulated outputs (built-in power supply)

Downloads

Condition New
Brand Altronix
Power Supply Type Cabinet, Wall Mount
Output Protection Fuses
Input Voltage 115 VAC
Output Voltage 12 VDC, 24 VDC
Output Current 3.0 Amp, 4.0 Amp
Features Battery Charger, Fire Alarm Disconnect, UL Listed
Output Type DC
Fire Alarm Interface Yes
Certifications CSFM, MEA, UL
Power Options 3 amp @ 24VDC, 4 amp @ 12VDC
Output Protection Fuse
Number of Outputs 8
Input Voltage 115VAC
Version Indoor Wallmount
Battery Charging Yes

Customers also viewed