Altronix ACM4 4 Output Access Power Controller Module, Fused Outputs

Altronix   |   SKU: ACM4   |   Model: ACM4

Product Highlights

4 Output Access Power Controller Module - Converts one (1) 12 to 24 volt AC or DC input into four (4) fused power outputs, individually selectable Fail-Safe/Fail-Secure outputs or dry form "C" contacts, fire alarm disconnect is selectable by output, UL Listed sub-assembly.
Qty:
$60.16
Add to Quote

Usually ships within 1-2 Weeks + Shipping Method

  • Free Lifetime Support
  • Free Warranty & Repair Service
  • Call for Bulk Pricing
Express Checkout:

ACM4 unit converts one (1) 12 to 24 volt AC or DC input into four (4) independently controlled fuse protected outputs. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The unit is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs.

Input:

  • 12 to 24 volt AC or DC operation (setting not required), (0.4 amp @ 12volt, 0.2 amp @ 24 volt current consumption with all relays energized).
  • Power supply input options:
    • One (1) common power input (board and lock power).
    • Two (2) isolated power inputs (one (1) for board power and one (1) for lock/accessory power).
  • Four (4) Access Control System trigger inputs:
    • Four (4) normally open (NO) inputs.
    • Four (4) open collector sink inputs.
    • Any combination of the above.

Output:

  • Four (4) independently controlled outputs:
    • Four (4) Fail-Safe and/or Fail-Secure power outputs.
    • Four (4) dry form "C" 5 amp rated relay outputs
    • Any combination of the above
  • Four (4) auxiliary power outputs (unswitched).
  • Output ratings:
    • Fuses are rated 3 amp each.
    • Main fuse is rated at 10 amp.
  • Note: Total output current is determined by the power supply, not to exceed a maximum of 10 amp total.

Features:

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the four (4) outputs.
  • Fire Alarm disconnect input options:
    • Normally open (NO) or normally closed (NC) dry contact input.
    • Polarity reversal input from FACP signaling circuit.
  • FACP output relay (form "C" contact rated @ 1 amp 28VDC not evaluated by UL).
  • Removable terminal blocks facilitate ease of installation.

Limited Lifetime Warranty

Downloads

pdf
(Size: 122.7 KB)
Condition New
Brand Altronix
PDU Type Basic
Total Outlets 4
Input Voltage 12V, 24V
Output Protection Fuses
Features Fire Alarm Interface
Number of Outputs 4
Output Protection Fuse
Enclosure No

ACM4 unit converts one (1) 12 to 24 volt AC or DC input into four (4) independently controlled fuse protected outputs. These power outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The unit is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs.

Input:

  • 12 to 24 volt AC or DC operation (setting not required), (0.4 amp @ 12volt, 0.2 amp @ 24 volt current consumption with all relays energized).
  • Power supply input options:
    • One (1) common power input (board and lock power).
    • Two (2) isolated power inputs (one (1) for board power and one (1) for lock/accessory power).
  • Four (4) Access Control System trigger inputs:
    • Four (4) normally open (NO) inputs.
    • Four (4) open collector sink inputs.
    • Any combination of the above.

Output:

  • Four (4) independently controlled outputs:
    • Four (4) Fail-Safe and/or Fail-Secure power outputs.
    • Four (4) dry form "C" 5 amp rated relay outputs
    • Any combination of the above
  • Four (4) auxiliary power outputs (unswitched).
  • Output ratings:
    • Fuses are rated 3 amp each.
    • Main fuse is rated at 10 amp.
  • Note: Total output current is determined by the power supply, not to exceed a maximum of 10 amp total.

Features:

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the four (4) outputs.
  • Fire Alarm disconnect input options:
    • Normally open (NO) or normally closed (NC) dry contact input.
    • Polarity reversal input from FACP signaling circuit.
  • FACP output relay (form "C" contact rated @ 1 amp 28VDC not evaluated by UL).
  • Removable terminal blocks facilitate ease of installation.

Limited Lifetime Warranty

Downloads

pdf
(Size: 122.7 KB)
Condition New
Brand Altronix
PDU Type Basic
Total Outlets 4
Input Voltage 12V, 24V
Output Protection Fuses
Features Fire Alarm Interface
Number of Outputs 4
Output Protection Fuse
Enclosure No

Customers also viewed

Check items to add to the cart or select all