Altronix T2MK75F16Q Access and Power Integration, Kit Includes Trove2 Enclosure with TM2 Backplane and TMV2 Door Backplane
Altronix
|
SKU: T2MK75F16Q
|
Model: T2MK75F16Q
Product Highlights
Altronix T2MK75F16Q Access and Power Integration, Kit Includes Trove2 Enclosure with TM2 Backplane and TMV2 Door Backplane
The T2MK75F16Q from Altronix is a pre-assembled and consist of Trove2M2 enclosure with factory installed Altronix power supply/charger(s) and sub-assemblies. This kit also accommodate various combinations of Mercury boards for up to sixteen (16) doors in a single enclosure.
Features
Input
- 120VAC 60Hz/8A
Output
- 12VDC up to 9.3A and 24VDC up to 9.2A max current
- Sixteen (16) Fail-Safe/Fail-Secure or Dry Form "C" Outputs
Back-up Battery (not included)
- Capacity: 12AH / 12VDC (Up to 4 within enclosure); 40 AH / 65 AH (requires separate enclosure)
- Type - Sealed lead acid or gel type
- Fuse Rating: 15A/32V
- Failover - Upon AC loss, instantaneous
Supervision
- AC Failure - Form "C" contacts
- Battery - Form "C" contacts
- Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply, Prevents deep battery discharge
LED Indicators
- Input - 120VAC is present
- DC Output - Powered
- Battery - Discharged or not connected
Condition | New |
---|---|
Brand | Altronix |
Output Type | DC |
Fire Alarm Interface | No |
Power Options | 9.3 amp @ 12VDC, 9.2 amp @ 24VDC |
Output Protection | Fuse |
Number of Outputs | 16 |
Input Voltage | 120VAC |
Battery Charging | Yes |
- Trove2 enclosure with TM2 backplane and TMV2 door backplane
- One (1) eFlow104NB and One (1) eFlow102NB - Power Supply/Charger
- One (1) LINQ2 - Network Communications Module
- Two (2) ACM8 - Fused Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PD8UL - Power Distribution Module
The T2MK75F16Q from Altronix is a pre-assembled and consist of Trove2M2 enclosure with factory installed Altronix power supply/charger(s) and sub-assemblies. This kit also accommodate various combinations of Mercury boards for up to sixteen (16) doors in a single enclosure.
Features
Input
- 120VAC 60Hz/8A
Output
- 12VDC up to 9.3A and 24VDC up to 9.2A max current
- Sixteen (16) Fail-Safe/Fail-Secure or Dry Form "C" Outputs
Back-up Battery (not included)
- Capacity: 12AH / 12VDC (Up to 4 within enclosure); 40 AH / 65 AH (requires separate enclosure)
- Type - Sealed lead acid or gel type
- Fuse Rating: 15A/32V
- Failover - Upon AC loss, instantaneous
Supervision
- AC Failure - Form "C" contacts
- Battery - Form "C" contacts
- Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply, Prevents deep battery discharge
LED Indicators
- Input - 120VAC is present
- DC Output - Powered
- Battery - Discharged or not connected
Condition | New |
---|---|
Brand | Altronix |
Output Type | DC |
Fire Alarm Interface | No |
Power Options | 9.3 amp @ 12VDC, 9.2 amp @ 24VDC |
Output Protection | Fuse |
Number of Outputs | 16 |
Input Voltage | 120VAC |
Battery Charging | Yes |
- Trove2 enclosure with TM2 backplane and TMV2 door backplane
- One (1) eFlow104NB and One (1) eFlow102NB - Power Supply/Charger
- One (1) LINQ2 - Network Communications Module
- Two (2) ACM8 - Fused Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PD8UL - Power Distribution Module