Altronix AL400ULACMJ Power Supply/Chargers w/Access Power Controllers
Product Highlights
Power Supply/Charger with Access Power Controller - 8 fused Class 2 power limited outputs provide 12VDC @ 4 amp or 24VDC @ 3 amp, outputs are individually selectable for Fail-Safe or Fail-Secure operation or as dry form "C" contacts, fire alarm disconnect is selectable by output, AC & battery monitoring, encl. 18"H x 14.5"W x 4.625"D, 115VAC input, UL Listed (UL294), CUL Listed.
AL400ULACMJ converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail Secure outputs with a total of 4 amp @ 12VDC or 3 amp @ 24VDC continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to triggerother auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
- Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC not evaluated by UL)
- Short circuit and thermal overload protection
- Fire Alarm disconnect input options
Downloads
Condition | New |
---|---|
Brand | Altronix |
Power Supply Type | Cabinet, Wall Mount |
# of Outputs | 8 |
Input Voltage | 115 VAC |
Output Voltage | 12 VDC, 24 VDC |
Output Current | 3.0 Amp, 4.0 Amp |
Output Protection | Fuses |
Features | Battery Charger, Fire Alarm Disconnect, UL Listed |
Number of Outputs | 8 |
Output Protection | Fuse |
Enclosure | Yes |
Power Supply/Charger with Access Power Controller - 8 fused Class 2 power limited outputs provide 12VDC @ 4 amp or 24VDC @ 3 amp, outputs are individually selectable for Fail-Safe or Fail-Secure operation or as dry form "C" contacts, fire alarm disconnect is selectable by output, AC & battery monitoring, encl. 18"H x 14.5"W x 4.625"D, 115VAC input, UL Listed (UL294), CUL Listed.
AL400ULACMJ converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail Secure outputs with a total of 4 amp @ 12VDC or 3 amp @ 24VDC continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to triggerother auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
- Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC not evaluated by UL)
- Short circuit and thermal overload protection
- Fire Alarm disconnect input options
Downloads
Condition | New |
---|---|
Brand | Altronix |
Power Supply Type | Cabinet, Wall Mount |
# of Outputs | 8 |
Input Voltage | 115 VAC |
Output Voltage | 12 VDC, 24 VDC |
Output Current | 3.0 Amp, 4.0 Amp |
Output Protection | Fuses |
Features | Battery Charger, Fire Alarm Disconnect, UL Listed |
Number of Outputs | 8 |
Output Protection | Fuse |
Enclosure | Yes |