Loading...

Altronix STRIKEIT1 Dual Panic Device Power Controller

Altronix   |   SKU: STRIKEIT1   |   Model: STRIKEIT1

Product Highlights

Altronix STRIKEIT1 Dual Panic Device Power Controller
Qty:
$333.64
Add to Quote

Usually ships within 1-2 Weeks + Shipping Method

  • Free Lifetime Support
  • Free Warranty & Repair Service
  • Call for Bulk Pricing
Express Checkout:

Dual Panic Device Power Controller - Independently or simultaneously controlled lock outputs for two 24VDC panic hardware devices with high inrush current requirements. Programmable 1 to 30 sec. timed lock release, Two follower relay outputs, Two delayed momentary relay outputs, One 12VDC & One 24VDC aux. power outputs rated @ 1 amp each, Fire Alarm disconnect, built-in battery charger, encl: 13.5"H x 13"W x 3.25"D, Accommodates up to 2 - 12VDC/7AH batteries, 115VAC input, UL Listed (UL294), cUL Listed. MEA & CSFM Approved. 

StrikeIt1 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current surge panic hardware locking devices demand. Each lock output has an adjustable relock delay timer. It will control a pair of doors simultaneously or independently control two individual doors. It has a follower relay for each output to trigger external relays, ADA push plate switches, etc. Delayed follower relays control automatic door operators for doors that are always locked or for doors that are unlocked during the business day. In addition, two un-switched auxiliary voltage outputs are provided for powering card readers, keypads, REX PIRs, electronic timers, relays, etc. A configurable FACP interface will either provide power or remove power to the lock outputs when activated. LED status indicators are provided to monitor AC power, FACP status and for lock output wiring supervision. Intelligent logic provides protection against accidental shorting of lock outputs.

  • Input 115VAC 60Hz, 6.3 amp
  • Two (2) NO trigger inputs
  • Input fuse rating: 6.3 amp
  • Green AC Power LED indicates 115VAC present
  • Red trigger input LEDs indicate panic device status/trouble (activated, short or open circuit)
  • Green Fire Alarm Interface (FAI) LED indicates
  • FACP disconnect is activated
  • Red Battery LED indicates low battery during AC failure and manual test
  • Green AC LED indicates loss of AC trouble (not active during manual test sequence)
  • Battery leads included
  • Battery fuse rating: 25A/32V
  • Maximum charge current 650mA.
  • Built-in charger for sealed lead acid or gel type batteries
  • Automatic switch over to stand-by battery when AC fails
  • When 7AH batteries are used, battery capacity for emergency stand-by is 30 minutes

Downloads

Condition New
Brand Altronix

Dual Panic Device Power Controller - Independently or simultaneously controlled lock outputs for two 24VDC panic hardware devices with high inrush current requirements. Programmable 1 to 30 sec. timed lock release, Two follower relay outputs, Two delayed momentary relay outputs, One 12VDC & One 24VDC aux. power outputs rated @ 1 amp each, Fire Alarm disconnect, built-in battery charger, encl: 13.5"H x 13"W x 3.25"D, Accommodates up to 2 - 12VDC/7AH batteries, 115VAC input, UL Listed (UL294), cUL Listed. MEA & CSFM Approved. 

StrikeIt1 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current surge panic hardware locking devices demand. Each lock output has an adjustable relock delay timer. It will control a pair of doors simultaneously or independently control two individual doors. It has a follower relay for each output to trigger external relays, ADA push plate switches, etc. Delayed follower relays control automatic door operators for doors that are always locked or for doors that are unlocked during the business day. In addition, two un-switched auxiliary voltage outputs are provided for powering card readers, keypads, REX PIRs, electronic timers, relays, etc. A configurable FACP interface will either provide power or remove power to the lock outputs when activated. LED status indicators are provided to monitor AC power, FACP status and for lock output wiring supervision. Intelligent logic provides protection against accidental shorting of lock outputs.

  • Input 115VAC 60Hz, 6.3 amp
  • Two (2) NO trigger inputs
  • Input fuse rating: 6.3 amp
  • Green AC Power LED indicates 115VAC present
  • Red trigger input LEDs indicate panic device status/trouble (activated, short or open circuit)
  • Green Fire Alarm Interface (FAI) LED indicates
  • FACP disconnect is activated
  • Red Battery LED indicates low battery during AC failure and manual test
  • Green AC LED indicates loss of AC trouble (not active during manual test sequence)
  • Battery leads included
  • Battery fuse rating: 25A/32V
  • Maximum charge current 650mA.
  • Built-in charger for sealed lead acid or gel type batteries
  • Automatic switch over to stand-by battery when AC fails
  • When 7AH batteries are used, battery capacity for emergency stand-by is 30 minutes

Downloads

Condition New
Brand Altronix

Customers also viewed