Altronix ACM4CBE 4 Output Access Power Controller Module, PTC Outputs
4 Output Access Power Controller Module - Converts one (1) 12 to 24 volt AC or DC input into four (4) PTC power outputs, individually selectable Fail-Safe/Fail-Secure outputs, fire alarm disconnect is selectable by output, encl. 8"H x 7.25"W x 3.5"D, UL Listed, cUL Listed.
ACM4CBE converts one (1) 12 to 24 volt AC or DC input into four (4) independently controlled PTC protected outputs. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Unit is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs
Input:
- 12 to 24 volt AC or DC operation (setting not required), (0.4 amp @ 12volt, 0.2 amp @ 24 volt current consumption with all relays energized).
- Power supply input options:
- One (1) common power input (board and lock power).
- Two (2) isolated power inputs (one (1) for board power and one (1) for lock/accessory power).
- Four (4) Access Control System trigger inputs:
- Four (4) normally open (NO) inputs.
- Four (4) open collector sink inputs.
- Any combination of the above.
Output:
- Four (4) independently controlled outputs:
- Four (4) Fail-Safe and/or Fail-Secure power outputs.
- Four (4) dry form "C" 5 amp rated relay outputs
- Output ratings:
- PTCs are rated 3 amp each.
- Main fuse is rated at 10 amp.
- Note: Total output current is determined by the power supply, not to exceed a maximum of 10 amp total.
Features:
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the four (4) outputs.
- Fire Alarm disconnect input options:
- Normally open (NO) or normally closed (NC) dry contact input.
- Polarity reversal input from FACP signaling circuit.
- FACP output relay (form "C" contact rated @ 1 amp 28VDC not evaluated by UL).
- Removable terminal blocks facilitate ease of installation.
Limited Lifetime Warranty
Downloads
Condition | New |
---|---|
Brand | Altronix |
PDU Type | Basic |
Total Outlets | 4 |
Output Protection | PTC |
Input Voltage | 12V, 24V |
Features | Fire Alarm Interface |
No of Outputs | 4 |
Output Protection | PTC |
Fire Alarm Interface | Yes |
Trigger Controlled Outputs | Yes |
Enclosure | No |
ACM4CBE converts one (1) 12 to 24 volt AC or DC input into four (4) independently controlled PTC protected outputs. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Unit is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs
Input:
- 12 to 24 volt AC or DC operation (setting not required), (0.4 amp @ 12volt, 0.2 amp @ 24 volt current consumption with all relays energized).
- Power supply input options:
- One (1) common power input (board and lock power).
- Two (2) isolated power inputs (one (1) for board power and one (1) for lock/accessory power).
- Four (4) Access Control System trigger inputs:
- Four (4) normally open (NO) inputs.
- Four (4) open collector sink inputs.
- Any combination of the above.
Output:
- Four (4) independently controlled outputs:
- Four (4) Fail-Safe and/or Fail-Secure power outputs.
- Four (4) dry form "C" 5 amp rated relay outputs
- Output ratings:
- PTCs are rated 3 amp each.
- Main fuse is rated at 10 amp.
- Note: Total output current is determined by the power supply, not to exceed a maximum of 10 amp total.
Features:
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the four (4) outputs.
- Fire Alarm disconnect input options:
- Normally open (NO) or normally closed (NC) dry contact input.
- Polarity reversal input from FACP signaling circuit.
- FACP output relay (form "C" contact rated @ 1 amp 28VDC not evaluated by UL).
- Removable terminal blocks facilitate ease of installation.
Limited Lifetime Warranty
Downloads
Condition | New |
---|---|
Brand | Altronix |
PDU Type | Basic |
Total Outlets | 4 |
Output Protection | PTC |
Input Voltage | 12V, 24V |
Features | Fire Alarm Interface |
No of Outputs | 4 |
Output Protection | PTC |
Fire Alarm Interface | Yes |
Trigger Controlled Outputs | Yes |
Enclosure | No |