Altronix FIRESWITCH108 4 Class A, 8 Class B NAC Power Supply, 24VDC @ 10A, Red BC400 Enclosure

Altronix   |   SKU: FIRESWITCH108   |   Model: FIRESWITCH108

Product Highlights

Altronix FIRESWITCH108 Managed NAC Power Extender
Qty:
$546.60
Add to Quote

Usually ships within 1-2 Weeks + Shipping Method

  • Free Lifetime Support
  • Free Warranty & Repair Service
  • Call for Bulk Pricing
Express Checkout:

The Altronix FireSwitch208 is a cost effective managed NAC Power Extender. It interfaces with 12 or 24VDC Fire Alarm Control Panels (FACP) to provide Notification Appliance Circuit expansion support, for additional horns/strobes to allow ADA compliancy. It also provides auxiliary power to support system accessories. It delivers electronically regulated and filtered 24VDC power to Class B or Class ANAC loop circuits. Additionally, a separate 1 amp auxiliary output for 4-wire smoke detectors is available. Alarm current can be divided between the eight (8) outputs for powering NAC devices. Outputs are rated at 2.5 amp max., and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). In non-alarm condition independent loop supervision for Class A and/or Class B FACP NAC circuits is provided. In the event of a loop trouble, the FACP will be notified via the steered input (input 1 or input 2). In addition, there are common trouble output terminals [NC, C, NO] which are used to indicate general loop/system trouble. Two (2) FACP signaling outputs can be employed and directed to control supervision and power delivery to any combination of the eight (8) outputs. It provides a programmable LCD display interface, plus an ethernet port interface for remote programmability and monitoring.

Features

  • Power input: 120VAC 60Hz, 4.8 amp
  • Two (2) Class A or two (2) Class B FACP inputs
  • Two (2) configurable inputs trigger via Class A or Class B FACP signal circuits(polarity reversal) or dry contacts
  • 24VDC voltage regulated power-limited NAC outputs
  • 10 amp max. total alarm current
  • 7 amp max.stand-by without battery back-up
  • 1 amp with battery back-up including dedicated Aux. output
  • For Canadian applications Stand-by with battery backup is limited to 0.45 amp
  • 2.5 amp max current per output
  • One (1) auxiliary output rated at 1 amp (regulated, battery backed up)
  • Any NAC can be configured as an Aux. output with or without battery back-up (special application only)
  • Eight (8) Class B or Four (4) Class A, or any combination of Class A and Class B circuits
  • Thermal and short circuit protection with auto reset
Condition New
Brand Altronix
Type Indoor Wallmount
Total Current (Amp) 10 amp
Number of Class A NACs 4
Number of Class B NACs 8
Remote Management Yes

The Altronix FireSwitch208 is a cost effective managed NAC Power Extender. It interfaces with 12 or 24VDC Fire Alarm Control Panels (FACP) to provide Notification Appliance Circuit expansion support, for additional horns/strobes to allow ADA compliancy. It also provides auxiliary power to support system accessories. It delivers electronically regulated and filtered 24VDC power to Class B or Class ANAC loop circuits. Additionally, a separate 1 amp auxiliary output for 4-wire smoke detectors is available. Alarm current can be divided between the eight (8) outputs for powering NAC devices. Outputs are rated at 2.5 amp max., and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). In non-alarm condition independent loop supervision for Class A and/or Class B FACP NAC circuits is provided. In the event of a loop trouble, the FACP will be notified via the steered input (input 1 or input 2). In addition, there are common trouble output terminals [NC, C, NO] which are used to indicate general loop/system trouble. Two (2) FACP signaling outputs can be employed and directed to control supervision and power delivery to any combination of the eight (8) outputs. It provides a programmable LCD display interface, plus an ethernet port interface for remote programmability and monitoring.

Features

  • Power input: 120VAC 60Hz, 4.8 amp
  • Two (2) Class A or two (2) Class B FACP inputs
  • Two (2) configurable inputs trigger via Class A or Class B FACP signal circuits(polarity reversal) or dry contacts
  • 24VDC voltage regulated power-limited NAC outputs
  • 10 amp max. total alarm current
  • 7 amp max.stand-by without battery back-up
  • 1 amp with battery back-up including dedicated Aux. output
  • For Canadian applications Stand-by with battery backup is limited to 0.45 amp
  • 2.5 amp max current per output
  • One (1) auxiliary output rated at 1 amp (regulated, battery backed up)
  • Any NAC can be configured as an Aux. output with or without battery back-up (special application only)
  • Eight (8) Class B or Four (4) Class A, or any combination of Class A and Class B circuits
  • Thermal and short circuit protection with auto reset
Condition New
Brand Altronix
Type Indoor Wallmount
Total Current (Amp) 10 amp
Number of Class A NACs 4
Number of Class B NACs 8
Remote Management Yes