Loading...

Macurco RD-6-W Refrigerant Fixed Gas Detector

Macurco   |   SKU: RD-6 WHITE   |   Model: 70-2900-0046-7

Product Highlights

Macurco RD-6-W Refrigerant Fixed Gas Detector

This item is discontinued. Call (866) 440-2288 for Replacement

The Macurco RD-6 is a low voltage, dual relay Refrigerant (REF) detector, controller and transducer. The RD-6 has select-able 4-20 mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of refrigerant gas and provide feedback and automatic exhaust fan control to help reduce refrigerant gas concentrations in industrial refrigeration, cold storage or other commercial applications. The RD-6 is a low level meter capable of detecting several refrigerants including R-22, R-134A, R-404A, R-407C and R-410A.

Select-able Options

  • Fan relay actuation: select-able at 100 (default), 150, 200, 250, 300, 350ppm
  • Output: Fan relay, Alarm relay and 4-20mA current loop
  • Controls: Digital display (0-1,000 ppm), buzzer, fan delay, fan minimum run-time

Installation

  • Mounts on a standard 4" x 4" electrical box
  • 5 A SPDT fan relay controls valves, louvers or exhaust fans
  • 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
  • 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
  • Factory calibrated

Other Features

  • Supervised system design: detector problem will cause the fan & alarm relay to activate
  • Long life solid-state sensor
  • ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
  • White housing

Location

A Macurco RD-6 is normally mounted low in the room on a wall or column one foot above the floor in a central area where air movement is generally good. Use the same spacing as for smoke detectors, 30-foot centers, 900 square feet per detector (84 sq. meters). The coverage depends on air movement within the room or facility. Extra detectors may be needed near any areas where people work or where the air is stagnant. The RD-6 mounts on a 4x4 electrical box supplied by the contractor. Do not install the RD-6 inside another box unless it has good air flow through it. Do NOT mount the RD-6 where the normal ambient temperature is below 0F or exceeds 125F (below -18C or above 52C).

Downloads

pdf
(Size: 193.2 KB)
pdf
(Size: 1.5 MB)
Condition New
NDAA Compliance No
Brand Macurco
Home Control Wi-Fi
Type Hardwired
Scene Indoor
  • (1) Refrigerant Fixed Gas Detector Controller & Transducer
  • Product Documentation
  • Two Year Warranty
Write Your Own Review
You're reviewing:Macurco RD-6-W Refrigerant Fixed Gas Detector
Your Rating

The Macurco RD-6 is a low voltage, dual relay Refrigerant (REF) detector, controller and transducer. The RD-6 has select-able 4-20 mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of refrigerant gas and provide feedback and automatic exhaust fan control to help reduce refrigerant gas concentrations in industrial refrigeration, cold storage or other commercial applications. The RD-6 is a low level meter capable of detecting several refrigerants including R-22, R-134A, R-404A, R-407C and R-410A.

Select-able Options

  • Fan relay actuation: select-able at 100 (default), 150, 200, 250, 300, 350ppm
  • Output: Fan relay, Alarm relay and 4-20mA current loop
  • Controls: Digital display (0-1,000 ppm), buzzer, fan delay, fan minimum run-time

Installation

  • Mounts on a standard 4" x 4" electrical box
  • 5 A SPDT fan relay controls valves, louvers or exhaust fans
  • 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
  • 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
  • Factory calibrated

Other Features

  • Supervised system design: detector problem will cause the fan & alarm relay to activate
  • Long life solid-state sensor
  • ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
  • White housing

Location

A Macurco RD-6 is normally mounted low in the room on a wall or column one foot above the floor in a central area where air movement is generally good. Use the same spacing as for smoke detectors, 30-foot centers, 900 square feet per detector (84 sq. meters). The coverage depends on air movement within the room or facility. Extra detectors may be needed near any areas where people work or where the air is stagnant. The RD-6 mounts on a 4x4 electrical box supplied by the contractor. Do not install the RD-6 inside another box unless it has good air flow through it. Do NOT mount the RD-6 where the normal ambient temperature is below 0F or exceeds 125F (below -18C or above 52C).

Downloads

pdf
(Size: 193.2 KB)
pdf
(Size: 1.5 MB)
Condition New
NDAA Compliance No
Brand Macurco
Home Control Wi-Fi
Type Hardwired
Scene Indoor
  • (1) Refrigerant Fixed Gas Detector Controller & Transducer
  • Product Documentation
  • Two Year Warranty
Write Your Own Review
You're reviewing:Macurco RD-6-W Refrigerant Fixed Gas Detector
Your Rating

Customers also viewed

Check items to add to the cart or select all