Loading...

Altronix T2M7XK1DV 8-Door Altronix/Mercury Access and Power Integration Wired Kit

Altronix   |   SKU: T2M7XK1DV   |   Model: T2M7XK1DV

Product Highlights

Altronix T2M7XK1DV 8-Door Altronix/Mercury Access and Power Integration Wired Kit
Qty:
$1,647.31
Add to Quote

Usually ships within 5-7 days + Shipping Method

  • Free Lifetime Support
  • Free Warranty & Repair Service
  • Call for Bulk Pricing
Express Checkout:

Altronix T2M7XK1DV is a 8-door access and power integration kit which includes Altronix power and sub-assemblies along with factory installed wire management and wire assemblies that are pre-configured with terminal blocks for Mercury* hardware. This unit provides ample power and dual voltage outputs to support Mercury platform controllers and locking devices. The T2M7XK1DV accommodates one (1) Intelligent Dual Reader Controller and three (3) Dual Reader Interface Modules. Trove Plus simplifies field installations and provides reliable, robust critical power and control for the most demanding applications.*Also compatible with these authentic Mercury partners:AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic i-PRO MonitorCast, Quintron, RS2, S2 Security, Schneider Electric, Vanderbilt

Features

eFlow104NBV Power Supply/Charger

Input

  • Voltage: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.7A
  • Main Fuse: 6.5A / 250V

Outputs

  • Voltage: 24VDC @ 10A
  • Auxiliary: 1A (unswitched)
  • Other: Overvoltage protection. Filtered and regulated

Battery Backup

  • Type: Sealed lead acid or gel type
  • Fuse Rating: 15A/32V
  • Failover: Upon AC loss, instantaneous

Fire Alarm Disconnect

  • Supervised: Latching or non-latching
  • EOL: 10K Resistor

Supervision

  • AC Failure: Form “C” contacts
  • Battery: Form “C” contacts
  • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge

Indicators LED

  • AC Input: 220VAC is present
  • DC Output: 24VDC is present
  • Battery: Discharged or not connected

ACMS8CB Dual Input Access Power Controller

Input

  • Voltage: 24VDC from eFlow104NBV and 12VDC from VR6
  • Input PTC: 9A

Outputs

  • Voltage: 24VDC
  • Eight (8) 24VDC independently controlled PTC outputs:
  • a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A
  • b) Auxiliary power outputs (unswitched)
  • c) Any combination of the above

Outputs Ratings

  • PTCs: 2.5A

Indicators (LED)

  • Red LEDs: Outputs are triggered (relays energized)
  • Green LED: FACP disconnect is triggered

VR6 Voltage Regulator

Input

  • Voltage: 24VDC from eFlow104NBV

Output

  • Voltage: 12VDC
  • Current: 6A continuous
  • Other: Surge suppression

Indicators LED

  • Input: 24VDC is present
  • Output: Powered

PDS8CB Dual Input Power Distribution Module

Input

  • Voltage: 12VDC from VR6 and 24VDC from eFlow104NBV
  • Input PTC: 9A

Outputs

  • Voltage: 12VDC and/or 24VDC
  • Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2
  • Individual outputs may be set to OFF position for servicing

Outputs Ratings

  • PTCs are rated 2.5A

Indicators (LED)

  • DC Output: Eight (8) individual output LEDs
  • Green: 12VDC
  • Red: 24VDC

Environmental

Temperature

  • Operating: 0° C to 49° C (32° F to 120° F)
  • Storage: - 20° C to 70° C ( - 4° F to 158° F)

Relative Humidity

  • Relative Humidity 85% +/- 5%

BTU/Hr (approx.):

  • 145 BTU/Hr
Condition New
Brand Altronix
NDAA Compliance No
Output Type DC
Certifications CE
Power Options 10 amp @ 24VDC
Output Protection PTC
Number of Outputs 8
Input Voltage 220VAC
Version Indoor wallmount

Altronix T2M7XK1DV is a 8-door access and power integration kit which includes Altronix power and sub-assemblies along with factory installed wire management and wire assemblies that are pre-configured with terminal blocks for Mercury* hardware. This unit provides ample power and dual voltage outputs to support Mercury platform controllers and locking devices. The T2M7XK1DV accommodates one (1) Intelligent Dual Reader Controller and three (3) Dual Reader Interface Modules. Trove Plus simplifies field installations and provides reliable, robust critical power and control for the most demanding applications.*Also compatible with these authentic Mercury partners:AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic i-PRO MonitorCast, Quintron, RS2, S2 Security, Schneider Electric, Vanderbilt

Features

eFlow104NBV Power Supply/Charger

Input

  • Voltage: 220VAC (working range 198VAC - 256VAC), 50/60Hz, 2.7A
  • Main Fuse: 6.5A / 250V

Outputs

  • Voltage: 24VDC @ 10A
  • Auxiliary: 1A (unswitched)
  • Other: Overvoltage protection. Filtered and regulated

Battery Backup

  • Type: Sealed lead acid or gel type
  • Fuse Rating: 15A/32V
  • Failover: Upon AC loss, instantaneous

Fire Alarm Disconnect

  • Supervised: Latching or non-latching
  • EOL: 10K Resistor

Supervision

  • AC Failure: Form “C” contacts
  • Battery: Form “C” contacts
  • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge

Indicators LED

  • AC Input: 220VAC is present
  • DC Output: 24VDC is present
  • Battery: Discharged or not connected

ACMS8CB Dual Input Access Power Controller

Input

  • Voltage: 24VDC from eFlow104NBV and 12VDC from VR6
  • Input PTC: 9A

Outputs

  • Voltage: 24VDC
  • Eight (8) 24VDC independently controlled PTC outputs:
  • a) Fail-Safe and/or Fail-Secure power outputs. Form “C” Relays rated 28VAC or VDC @ 2.5A
  • b) Auxiliary power outputs (unswitched)
  • c) Any combination of the above

Outputs Ratings

  • PTCs: 2.5A

Indicators (LED)

  • Red LEDs: Outputs are triggered (relays energized)
  • Green LED: FACP disconnect is triggered

VR6 Voltage Regulator

Input

  • Voltage: 24VDC from eFlow104NBV

Output

  • Voltage: 12VDC
  • Current: 6A continuous
  • Other: Surge suppression

Indicators LED

  • Input: 24VDC is present
  • Output: Powered

PDS8CB Dual Input Power Distribution Module

Input

  • Voltage: 12VDC from VR6 and 24VDC from eFlow104NBV
  • Input PTC: 9A

Outputs

  • Voltage: 12VDC and/or 24VDC
  • Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2
  • Individual outputs may be set to OFF position for servicing

Outputs Ratings

  • PTCs are rated 2.5A

Indicators (LED)

  • DC Output: Eight (8) individual output LEDs
  • Green: 12VDC
  • Red: 24VDC

Environmental

Temperature

  • Operating: 0° C to 49° C (32° F to 120° F)
  • Storage: - 20° C to 70° C ( - 4° F to 158° F)

Relative Humidity

  • Relative Humidity 85% +/- 5%

BTU/Hr (approx.):

  • 145 BTU/Hr
Condition New
Brand Altronix
NDAA Compliance No
Output Type DC
Certifications CE
Power Options 10 amp @ 24VDC
Output Protection PTC
Number of Outputs 8
Input Voltage 220VAC
Version Indoor wallmount

Customers also viewed

Check items to add to the cart or select all