Altronix T2MK74D 4-Door Altronix/Mercury Access and Power Integration Kit
Product Highlights
Altronix T2MK74D kit consists of Trove2 enclosure and TM2 Altronix & Mercury backplane with 24VDC @ 10A power supply/charger, four (4) PTC protected output access control module and eight (8) PTC protected output power distribution module. This kit also accommodates various combinations of Mercury* boards for up to four (4) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.*Also compatible with these authentic Mercury partners:AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt
Features
AL1024ULXB2 Power Supply/Charger
Input
- Voltage: 115VAC 60Hz, 4.2A max
- Main Fuse: 5A / 250V
Outputs
- Voltage: 24VDC
- Current: 10A @ 24VDC continuous max
- Other: Overvoltage protection. Filtered and regulated
Battery Backup
- Capacity: 12AH /12VDC (2 within enclosure), 40 AH / 65 AH (requires separate enclosure)
- Type: Sealed lead acid or gel type
- Failover: Upon AC loss, instantaneous
Supervision
- AC Failure: Form “C” contacts
- Battery: Form “C” contacts
Indicators LED
- Input: 115VAC is present
- DC Output: Powered
- Battery: Discharged or not connected
ACM4CB Access Power Controller
Input
- Voltage: 24VDC from AL1024ULXB2
- Main Fuse: 10A / 32V
Outputs
- Class 2 power-limited auto-resettable outputs
- Voltage: 24VDC
- Four (4) independently controlled 2.5A outputs:
- a) Four (4) Fail-Safe and/or Fail-Secure power outputs
- b) Four (4) dry form “C” 5A rated relay outputs
- c) Any combination of the above
- Four (4) auxiliary power outputs (unswitched)
Outputs Ratings
- PTCs: 2.5A
Indicators (LED)
- Red LEDs: Outputs are triggered (relays energized)
- Green LED: FACP disconnect is triggered
PD8ULCB Power Distribution Module
Input
- Voltage: 24VDC from AL1024ULXB2
Outputs
- Class 2 power-limited auto-resettable outputs
- Voltage: 24VDC
- PTCs: 2.5A
Indicators LED
- Green LED: DC Output
Environmental
Temperature
- Operating: 0° C to 49° C (32° F to 120° F)
- Storage: - 20° C to 70° C ( - 4° F to 158° F)
Relative Humidity
- Relative Humidity 85% +/- 5%
BTU/Hr (approx.):
- 145 BTU/Hr
Condition | New |
---|---|
Brand | Altronix |
NDAA Compliance | No |
Output Type | DC |
Certifications | CE |
Power Options | 10 amp @ 24VDC |
Output Protection | Fuse |
Number of Outputs | 4 |
Input Voltage | 115VAC |
Version | Indoor wallmount |
Altronix T2MK74D kit consists of Trove2 enclosure and TM2 Altronix & Mercury backplane with 24VDC @ 10A power supply/charger, four (4) PTC protected output access control module and eight (8) PTC protected output power distribution module. This kit also accommodates various combinations of Mercury* boards for up to four (4) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.*Also compatible with these authentic Mercury partners:AccessNsite, Avigilon, BadgePass, BluBox, Feenics, Genetec, Identicard, IMRON, Johnson Controls, Kastle, Keri Systems, Lenel/S2, LockState, Maxxess, Midpoint Security, NLSS, Open Options, Panasonic Video Insight, Quintron, RS2, Schneider Electric, Vanderbilt
Features
AL1024ULXB2 Power Supply/Charger
Input
- Voltage: 115VAC 60Hz, 4.2A max
- Main Fuse: 5A / 250V
Outputs
- Voltage: 24VDC
- Current: 10A @ 24VDC continuous max
- Other: Overvoltage protection. Filtered and regulated
Battery Backup
- Capacity: 12AH /12VDC (2 within enclosure), 40 AH / 65 AH (requires separate enclosure)
- Type: Sealed lead acid or gel type
- Failover: Upon AC loss, instantaneous
Supervision
- AC Failure: Form “C” contacts
- Battery: Form “C” contacts
Indicators LED
- Input: 115VAC is present
- DC Output: Powered
- Battery: Discharged or not connected
ACM4CB Access Power Controller
Input
- Voltage: 24VDC from AL1024ULXB2
- Main Fuse: 10A / 32V
Outputs
- Class 2 power-limited auto-resettable outputs
- Voltage: 24VDC
- Four (4) independently controlled 2.5A outputs:
- a) Four (4) Fail-Safe and/or Fail-Secure power outputs
- b) Four (4) dry form “C” 5A rated relay outputs
- c) Any combination of the above
- Four (4) auxiliary power outputs (unswitched)
Outputs Ratings
- PTCs: 2.5A
Indicators (LED)
- Red LEDs: Outputs are triggered (relays energized)
- Green LED: FACP disconnect is triggered
PD8ULCB Power Distribution Module
Input
- Voltage: 24VDC from AL1024ULXB2
Outputs
- Class 2 power-limited auto-resettable outputs
- Voltage: 24VDC
- PTCs: 2.5A
Indicators LED
- Green LED: DC Output
Environmental
Temperature
- Operating: 0° C to 49° C (32° F to 120° F)
- Storage: - 20° C to 70° C ( - 4° F to 158° F)
Relative Humidity
- Relative Humidity 85% +/- 5%
BTU/Hr (approx.):
- 145 BTU/Hr
Condition | New |
---|---|
Brand | Altronix |
NDAA Compliance | No |
Output Type | DC |
Certifications | CE |
Power Options | 10 amp @ 24VDC |
Output Protection | Fuse |
Number of Outputs | 4 |
Input Voltage | 115VAC |
Version | Indoor wallmount |