Loading...

Altronix EFLOW104NX16V Power Supply Charger, 16 Fused Outputs, 24VDC @ 10A, Aux Output, FAI, LinQ2 Ready

Altronix   |   SKU: EFLOW104NX16V   |   Model: EFLOW104NX16V

Product Highlights

Altronix EFLOW104NX16V Power Supply Charger, 16 Fused Outputs, 24VDC @ 10A, Aux Output, FAI, LinQ2 Ready
Qty:
$365.46
Add to Quote

Usually ships within 5-7 days + Shipping Method

  • Free Lifetime Support
  • Free Warranty & Repair Service
  • Call for Bulk Pricing
Express Checkout:

Altronix eFlow104NX16V is a power supply/charger that converts a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into sixteen fuse protected 24VDC outputs with a total of 10A max. The unit includes an unswitched aux. output. It also offers a suite of features that includes fire alarm disconnect, overvoltage protection, and low power disconnect which prevents deep discharge of stand-by batteries.

Input
  • 120VAC (working range 198VAC - 256VAC), 50/60Hz, 2.7A
  • Input fuse: 5A/250V
Output
  • Sixteen (16) fuse protected outputs
  • Outputs are rated @ 2.5A
  • 24VDC @ 10A supply current
  • Auxiliary output rated @ 1A (unswitched)
  • Overvoltage protection
Battery Backup
  • Built-in charger for sealed lead acid or gel type batteries
  • Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous with no interruption
Supervision
  • AC fail supervision (form "C" contacts)
  • Notification trigger is selectable for 30 seconds (factory set) or 2 hours
  • Battery fail and presence supervision (form "C" contacts)
  • Low power shutdown. Shuts down DC output terminals if battery voltage drops below 70-75% (depending on the power supply). Prevents deep battery discharge
Fire Alarm Disconnect
  • Supervised Fire Alarm disconnect (latching or non-latching) 10K EOL resistor. Operates on a normally open (NO) or normally closed (NC) trigger
Electrical
Temperature
  • Operating: 0° C to 49° C (32° F to 120° F)
  • Storage: - 20° C to 70° C ( - 4° F to 158° F)
  • Relative Humidity 85% +/- 5%
  • BTU/Hr (approx.): 123 BTU/Hr
  • System AC input VA requirement: 594VA
  • Visual Indicators
    • Green AC Power LED indicates 120VAC present
    • AC input and DC output LED indicators
    Additional Features
    • Short circuit and overload protection
    • Unit is complete with power supply, enclosure, battery leads, and cam lock
    Condition New
    Brand Altronix
    NDAA Compliance No
    Type Indoor Wallmount
    Output Type DC
    Power Options 10 amp @ 24VDC
    Input Voltage 120VAC
    Number of Outputs 16
    Output Protection Fuse
    Fire Alarm Interface Yes
    Battery Charging Yes
    Certification CE

    Altronix eFlow104NX16V is a power supply/charger that converts a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into sixteen fuse protected 24VDC outputs with a total of 10A max. The unit includes an unswitched aux. output. It also offers a suite of features that includes fire alarm disconnect, overvoltage protection, and low power disconnect which prevents deep discharge of stand-by batteries.

    Input
    • 120VAC (working range 198VAC - 256VAC), 50/60Hz, 2.7A
    • Input fuse: 5A/250V
    Output
    • Sixteen (16) fuse protected outputs
    • Outputs are rated @ 2.5A
    • 24VDC @ 10A supply current
    • Auxiliary output rated @ 1A (unswitched)
    • Overvoltage protection
    Battery Backup
    • Built-in charger for sealed lead acid or gel type batteries
    • Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous with no interruption
    Supervision
    • AC fail supervision (form "C" contacts)
    • Notification trigger is selectable for 30 seconds (factory set) or 2 hours
    • Battery fail and presence supervision (form "C" contacts)
    • Low power shutdown. Shuts down DC output terminals if battery voltage drops below 70-75% (depending on the power supply). Prevents deep battery discharge
    Fire Alarm Disconnect
    • Supervised Fire Alarm disconnect (latching or non-latching) 10K EOL resistor. Operates on a normally open (NO) or normally closed (NC) trigger
    Electrical
    Temperature
    • Operating: 0° C to 49° C (32° F to 120° F)
    • Storage: - 20° C to 70° C ( - 4° F to 158° F)
  • Relative Humidity 85% +/- 5%
  • BTU/Hr (approx.): 123 BTU/Hr
  • System AC input VA requirement: 594VA
  • Visual Indicators
    • Green AC Power LED indicates 120VAC present
    • AC input and DC output LED indicators
    Additional Features
    • Short circuit and overload protection
    • Unit is complete with power supply, enclosure, battery leads, and cam lock
    Condition New
    Brand Altronix
    NDAA Compliance No
    Type Indoor Wallmount
    Output Type DC
    Power Options 10 amp @ 24VDC
    Input Voltage 120VAC
    Number of Outputs 16
    Output Protection Fuse
    Fire Alarm Interface Yes
    Battery Charging Yes
    Certification CE

    Customers also viewed

    Check items to add to the cart or select all