Altronix MOM5C 5 Output Power Distribution Module for Access Control
Product Highlights
5 Output Access Power Distribution Module - Converts one (1) 12VDC or 24VDC input into five (5) power outputs, PTC Class 2 power limited outputs rated @ 2.5 amp, Fire Alarm interface, encl. 8"H x 7.25"W x 3.5"D. UL Listed (UL294/UL1481), CSFM & MEA Approved.
MOM5C multi output power distribution module converts one (1) non-power limited DC voltage input to five (5) power limited outputs. Each output will route power to a variety of access control hardware and devices which includes Mag Locks, Electric Strikes, Magnetic Door Holders, etc... These outputs will operate in both fail-safe and fail-secure modes. Controlled trigger input is achieved through normally open (NO) or normally closed (NC) supervised input or the polarity reversal from an FACP (Fire Alarm Control Panel). A form "C" dry output relay will enable HVAC Shutdown, Elevator Recall or trigger auxiliary devices.
- 12VDC or 24VDC from power supply
- 12VDC or 24VDC selectable outputs
- Five (5) individual power-limited class 2 outputs
- Current limit is 2 amp @ 12VDC or 24VDC per output
- Fire Alarm Panel or Access Control System trigger inputs, (N.O. or N.C. supervised trigger input and polarity reversal trigger input)
- Interfaces with most UL Listed Power Supplies
Downloads
Condition | New |
---|---|
Brand | Altronix |
No of Outputs | 5 |
Output Protection | PTC |
Fire Alarm Interface | Yes |
Trigger Controlled Outputs | No |
Enclosure | Yes |
5 Output Access Power Distribution Module - Converts one (1) 12VDC or 24VDC input into five (5) power outputs, PTC Class 2 power limited outputs rated @ 2.5 amp, Fire Alarm interface, encl. 8"H x 7.25"W x 3.5"D. UL Listed (UL294/UL1481), CSFM & MEA Approved.
MOM5C multi output power distribution module converts one (1) non-power limited DC voltage input to five (5) power limited outputs. Each output will route power to a variety of access control hardware and devices which includes Mag Locks, Electric Strikes, Magnetic Door Holders, etc... These outputs will operate in both fail-safe and fail-secure modes. Controlled trigger input is achieved through normally open (NO) or normally closed (NC) supervised input or the polarity reversal from an FACP (Fire Alarm Control Panel). A form "C" dry output relay will enable HVAC Shutdown, Elevator Recall or trigger auxiliary devices.
- 12VDC or 24VDC from power supply
- 12VDC or 24VDC selectable outputs
- Five (5) individual power-limited class 2 outputs
- Current limit is 2 amp @ 12VDC or 24VDC per output
- Fire Alarm Panel or Access Control System trigger inputs, (N.O. or N.C. supervised trigger input and polarity reversal trigger input)
- Interfaces with most UL Listed Power Supplies
Downloads
Condition | New |
---|---|
Brand | Altronix |
No of Outputs | 5 |
Output Protection | PTC |
Fire Alarm Interface | Yes |
Trigger Controlled Outputs | No |
Enclosure | Yes |